IP67 is a pass/fail rating, not a leak rate. On a production line it becomes an air or tracer-gas test with a limit. Here is how the main methods compare, and what changes for small sealed parts such as connectors.
Electric-vehicle battery packs have to keep water and dust out for the life of the car. One equipment maker notes that packs must meet IP67, and harsher locations may call for IP69. There is no single worldwide method for proving it on the line, so the test method is an engineering decision you make together with your customer.
One vendor (INFICON) publishes example limits: about 1×10⁻⁴ mbar·l/s if a few drops of water are tolerable, and 2×10⁻⁵ mbar·l/s if no water may enter. It also notes that air and helium leak rates differ by the ratio of the gases' viscosities. These are vendor figures for illustration, not a standard. Your limit comes from your drawing or customer specification.
Sensitivity and speed trade off against cost.
| Method | How it works | Strengths | Limits |
|---|---|---|---|
| Pressure decay (absolute or differential) | Fill the part with air, isolate it, and watch the pressure fall over a set time. Differential versions compare against a sealed reference. | Low cost, simple, no tracer gas | Longer test time; affected by temperature change and part swelling; small leaks in large volumes are hard to see |
| Mass flow | Hold the part at test pressure and measure the air flow needed to keep it there. | Reads the leak directly and works well on larger leaks | Generally less sensitive than tracer gas; needs a stable supply pressure |
| Helium tracer (vacuum chamber, sniffer or accumulation) | Fill with helium or a helium mix and detect it outside the part with a mass spectrometer. | Highest sensitivity and shorter test times | Higher equipment cost, helium supply, and fixtures or chambers to build |
| Water immersion (bubble test) | Submerge the pressurised part and look for bubbles or water ingress. | Easy to understand | Slow, depends on the operator, can damage a battery; not suited to a fast line |
The relative sensitivity and cost of helium and pressure decay are widely reported, for example by Adlema. Sources differ on cooling circuits: because air pressure decay is sensitive to temperature changes, some recommend helium accumulation for cooling-system parts. Follow the specification and validation data for your own part rather than a general rule.
Our engineering view, from building automated connector-seal testers for the automotive industry.
General technical information from the sources listed below, read in November 2026. Some leak-rate figures come from vendor material. Always validate a method on your own part against your customer's specification.
Tell us about your part, the leak limit and the cycle time. We design turnkey automated leak-testing systems.